Error:Each physical network must be connected to exactly one Solver Configuration block. There is no Solver Configuration block connected to Physical Network with the following blocks
600 views (last 30 days)
Show older comments
I had connected a solver configuration block in my model but these error is popping up when i connect a "current-Voltage simscape interface" block in my model.Kindly guide me in solving this problem. Thanking you, Saideep.
0 Comments
Answers (4)
Yogeshwar Bala
on 6 Oct 2018
Connect an "Electrical Reference" block to your ground line and add a Solver Configuration block with default value of f(x) = 0 to it.
5 Comments
Huang YanMing
on 4 Mar 2024
To add a "Solver Configuration"
Go to library browser and find it in the below folder
Simscape>Utilities
Behnam Mohammad
on 15 Jan 2020
What happens when you have multiple subsystems and each subsystem has an individual solver?
0 Comments
ever steeven nevarez cedeño
on 31 Aug 2021
tengo un problema similar pero al reves el problema es cuando lo pongo
Joel Van Sickel
on 10 Jun 2024
This specific problem happens from the interface block. Those blocks are used to decouple simscape networks and if you look under the hood, you will see they are connected by simulink wires, not simscape wires. This means that if you use one, you will now have an additional simscape network, so you will need to add an additional simscape configuration block to the side of the network that doesn't already have one. Or you will need to add it to both sides if neither side has one.