Clear Filters
Clear Filters

unable to resolve cooling plate error

2 views (last 30 days)
hi there,
i am modelling a battery module with cooling plate. while running the simulation, i am getting this error;
"Error compiling Simscape network for model molicell_module_with_cooling_plate.
Caused by:
Connection 'connect(NewModule.BottomExtClnt,Parallel_Channels.Side1)' is found to be connecting arrays of nodes of inconsistent sizes: '1x14' and '1x196'. The arguments in a connection must be of the same size."
kindly help in resolving this error. Thanks
  3 Comments
SUDEEP SINGH RAWAT
SUDEEP SINGH RAWAT on 26 Jul 2023
Thanks for responding sir. I have used battery builder app to build the battery module with 14X14 cylindrical cells. ambient coolant path and coolant thermal path are set to " cell based internal resistance". i have attached the model along with cooling plate parameters.i am not sure if the parameters of cooling plate matching with nodes of battery module? please help.
Hyunwoo
Hyunwoo on 27 Jul 2023
I have the same problem, did you solve it?

Sign in to comment.

Accepted Answer

Joel Van Sickel
Joel Van Sickel on 28 Jul 2023
I think you need to set your number of nodes to 14 and not 14x14 for the cooling plate. If that doesn't solve it, please share your model instead of screen shots to get further assistance.