Why do I encounter an error message when I attempt to generate code for a Xilinx System Generator Subsystem?
4 views (last 30 days)
Show older comments
MathWorks Support Team
on 13 Dec 2016
Answered: MathWorks Support Team
on 9 Jan 2017
Why do I encounter an error message when I attempt to generate code for a Xilinx System Generator Subsystem?
The error message I am encountering is as follows:
Error: Evaluation of elaborate function on class hdldefaults.XilinxVivadoSystemGeneratorSubsystem failed with the error message: hdlcoder:pirudd:PirUDMethodInfoError: hdlblackbox_com:setInputPortName:invalidIndex: Error: Invalid input port index 5, <Component CtxName = "SimulinkModelName" Refnum="XXX" UserName="SubsystemX" RTTIClass ="class pir::XsgVivadoComp" Network="n0"/> has 6 input port(s)
Accepted Answer
MathWorks Support Team
on 13 Dec 2016
These types of error messages are often encountered if the Xilinx System Generator Subsystem is not in accordance with the requirements listed in the documentation page "<https://www.mathworks.com/help/hdlcoder/ug/code-generation-with-xilinx-system-generator-subsystems.html Create a Xilinx System Generator Subsystem>".
For instance, a common mistake is to split input signals into branches, which is not supported. All inputs in the Subsystem need to be directly connected to Gateway In blocks and there should be a one-to-one correspondence.
0 Comments
More Answers (0)
See Also
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!