Hallo
We have an altrea FPGA, we are generating the design using simulink and then use the hdl coder to generate the vhdl code. We use the generated vhdl project file in quartus to download the program in our fpga. we get an warning from altera which is the following
Rule R102: External reset signals should be synchronized using two cascaded registers
we are currently using an Asynchronous reset, because synchronous reset uses a lot of resources, which leads to speed issue.
how can we solve this problem from simulink?
0 Comments
Answers (1)
Kiran Kintali
on 1 Nov 2020
These page describes how to generate code with synchronous or asynchronous reset.
web(fullfile(docroot, 'hdlcoder/ug/reset-and-clock-enable-settings.html'))
Asynchronous
Use asynchronous reset logic. This reset logic samples the reset independent of the clock signal.
The following process block, generated by a Unit Delay block, illustrates the use of asynchronous resets. When the reset signal is asserted, the process block performs a reset, without checking for a clock event.
Unit_Delay1_process : PROCESS (clk, reset)
BEGIN
IF reset = '1' THEN
Unit_Delay1_out1 <= (OTHERS => '0');
ELSIF clk'event AND clk = '1' THEN
IF clk_enable = '1' THEN
Unit_Delay1_out1 <= signed(x_in);
END IF;
END IF;
END PROCESS Unit_Delay1_process;
web(fullfile(docroot, 'hdlcoder/ug/guidelines-for-clock-and-reset-signals.html'))
web(fullfile(docroot, 'hdlcoder/ug/check-for-global-reset-setting-for-xilinx-and-altera-devices.html'))