Why does the code generated using the 'Build subsystem...' with Real-Time Workshop 5.1 (R13SP1) use the default step size instead of the specified step size?
Show older comments
The code generated using the 'Build subsystem...' with Real-Time Workshop 5.1 (R13SP1) uses the default step size instead of the specified step size.
The default step size is (Tstop - Tstart) / 50.
This problem only occurs if the solver is set to fixed-step, subsystem contains only continuous time blocks with inherited sample times, and the subsystem does not contain a continuous state.
Accepted Answer
More Answers (0)