connect
Block diagram interconnections of dynamic systems
Syntax
sysc = connect(sys1,...,sysN,inputs,outputs)
sysc = connect(sys1,...,sysN,inputs,outputs,APs)
sysc = connect(blksys,connections,inputs,outputs)
sysc = connect(___,opts)
Description
connects the block diagram elements sysc
= connect(sys1,...,sysN
,inputs
,outputs
)sys1,...,sysN
based on signal
names. The block diagram elements sys1,...,sysN
are dynamic system models. These models can include
summing junctions that you create using sumblk
. The connect
command interconnects the block
diagram elements by matching the input and output signals that you specify in the
InputName
and OutputName
properties of
sys1,...,sysN
. The aggregate model sysc
is
a dynamic system model having inputs and outputs specified by
inputs
and outputs
respectively.
inserts an sysc
= connect(sys1,...,sysN
,inputs
,outputs
,APs
)AnalysisPoint
at every signal location
specified in APs
. Use analysis points to mark locations of interest
which are internal signals in the aggregate model. For instance, a location at which you
want to extract a loop transfer function or measure the stability margins is a location
of interest.
uses index-based interconnection to build sysc
= connect(blksys
,connections
,inputs
,outputs
)sysc
out of an aggregate,
unconnected model blksys
. The matrix
connections
specifies how the outputs and inputs of
blksys
interconnect. For index-based interconnections,
inputs
and outputs
are index vectors that
specify which inputs and outputs of blksys
are the external inputs
and outputs of sysc
. This syntax can be convenient when you do not
want to assign names to all inputs and outputs of all models to connect. However, in
general, it is easier to keep track of named signals.
builds the interconnected model using additional options. You can use
sysc
= connect(___,opts
)opts
with the input arguments of any of the previous
syntaxes.
Input Arguments
|
Dynamic
system models that correspond to the elements of your block
diagram. For example, the elements of your block diagram can include one or
more |
|
For name-based interconnection, a character vector or cell array of
character vectors that specify the inputs of the aggregate model
|
|
For name-based interconnection, a character vector or cell array of
character vectors that specify the outputs of the aggregate model
|
|
Locations (internal signals) of interest in the aggregate model, specified
as a character vector or cell array of character vectors, such as
|
|
Unconnected aggregate model. To obtain blksys = append(C,G,S) |
|
Matrix that specifies the connections and summing junctions of the block
diagram. Each row of [3 2 0 0] specifies that [7 2 -15 6] indicates that If you do not specify any connection for a particular input or output,
|
|
Additional options for interconnection, specified as an options set that
you create with |
Output Arguments
|
Interconnected system, returned as either a state-space model or frequency-response model. The type of model returned depends on the input models. For example:
By default, opt = connectOptions('Simplify',false); sysc = connect(sys1,sys2,sys3,'r','y',opt); |
Examples
SISO Feedback Loop
Create an aggregate model of the following block diagram from r
to y
.
Create C
and G
, and name the inputs and
outputs.
C = pid(2,1); C.u = 'e'; C.y = 'u'; G = zpk([],[-1,-1],1); G.u = 'u'; G.y = 'y';
The notations C.u
and C.y
are shorthand
expressions equivalent to C.InputName
and
C.OutputName
, respectively. For example, entering
C.u = 'e'
is equivalent to entering C.InputName =
'e'
. The command sets the InputName
property of
C
to the value 'e'
.
Create the summing junction.
Sum = sumblk('e = r - y');
Combine C
, G
, and the summing junction to
create the aggregate model from r
to y
.
T = connect(G,C,Sum,'r','y');
connect
automatically joins inputs and outputs with matching
names.
MIMO Feedback Loop
Create the control system of the previous example where G
and
C
are both 2-input, 2-output models.
C = [pid(2,1),0;0,pid(5,6)]; C.InputName = 'e'; C.OutputName = 'u'; G = ss(-1,[1,2],[1;-1],0); G.InputName = 'u'; G.OutputName = 'y';
When you specify single names for vector-valued signals, the software
automatically performs vector expansion of the signal names. For example, examine
the names of the inputs to C
.
C.InputName
ans = 'e(1)' 'e(2)'
Create a 2-input, 2-output summing junction.
Sum = sumblk('e = r-y',2);
sumblk
also performs vector
expansion of the signal names.
Interconnect the models to obtain the closed-loop system.
T = connect(G,C,Sum,'r','y');
The block diagram elements G
, C
, and
Sum
are all 2-input, 2-output models. Therefore,
connect
performs the same vector expansion.
connect
selects all entries of the two-input signals
'r'
and 'y'
as inputs and outputs to
T
, respectively. For example, examine the input names of
T
.
T.InputName
ans = 'r(1)' 'r(2)'
Feedback Loop With Analysis Point Inserted by connect
Create a model of the following block diagram from r to y. Insert an analysis point at an internal location, u.
Create C
and G
, and name the inputs and outputs.
C = pid(2,1); C.InputName = 'e'; C.OutputName = 'u'; G = zpk([],[-1,-1],1); G.InputName = 'u'; G.OutputName = 'y';
Create the summing junction.
Sum = sumblk('e = r - y');
Combine C
, G
, and the summing junction to create the aggregate model, with an analysis point at u.
T = connect(G,C,Sum,'r','y','u')
Generalized continuous-time state-space model with 1 outputs, 1 inputs, 3 states, and the following blocks: AnalysisPoints_: Analysis point, 1 channels, 1 occurrences. Type "ss(T)" to see the current value and "T.Blocks" to interact with the blocks.
The resulting T
is a genss
model. The connect
command creates the AnalysisPoint
block, AnalysisPoints_
, and inserts it into T
. To see the name of the analysis point channel in AnalysisPoints_
, use getPoints
.
getPoints(T)
ans = 1x1 cell array
{'u'}
The analysis point channel is named 'u'
. You can use this analysis point to extract system responses. For example, the following commands extract the open-loop transfer at u and the closed-loop response at y to a disturbance injected at u.
L = getLoopTransfer(T,'u',-1); Tuy = getIOTransfer(T,'u','y');
T
is equivalent to the following block diagram, where AP_u designates the AnalysisPoint
block AnalysisPoints_
with channel name u.
Index-Based Interconnection
Create an aggregate model of the following block diagram from r
to y
using index-based interconnection.
Create C
, G
, and the unconnected aggregate
model blksys
.
C = pid(2,1); G = zpk([],[-1,-1],1); blksys = append(C,G);
The inputs u(1),u(2)
of blksys
correspond to
the inputs of C
and G
, respectively. The
outputs w(1),w(2)
of blksys
correspond to the
outputs of C
and G
, respectively.
Create the matrix connections
, which specifies which outputs of
blksys
connect to which inputs of blksys
.
connections = [2 1; 1 -2];
The first row indicates that w(1)
connects to
u(2)
; in other words, that the output of C
connects to the input of G
. The second row indicates that
-w(2)
connects to u(1)
; in other words,
that the negative of the output of G
connects to the input of
C
.
Create the connected aggregate model from r
to
y
.
T = connect(blksys,connections,1,2)
The last two arguments specify the external inputs and outputs in terms of the
indices of blksys
. The argument 1
specifies
that the external input connects to u(1)
. The last argument,
2
, specifies that the external output connects from
w(2)
.
Version History