sdo.requirements.PZDampingRatio
Damping ratio bound
Description
Specify bounds on the damping ratio of the poles of a linear system. You can then
      optimize the model response to meet these bounds using sdo.optimize. You can also use this object to specify overshoot bound. 
You must have Simulink® Control Design™ software to specify damping ratio requirements.
Creation
Syntax
Description
          creates a dampReq = sdo.requirements.PZDampingRatiosdo.requirements.PZDampingRatio object and assigns default
          values to its properties.
 specifies one or
          more properties using name-value
          arguments. For example, dampReq =
sdo.requirements.PZDampingRatio(Name=Value)dampReq =
            sdo.requirements.PZDampingRatio(DampingRatio=0.8) creates an
            sdo.requirements.PZDampingRatio object and sets the damping ratio to
            0.8
Before R2021a, use commas to separate each name and value, and enclose
            Name in quotes. For example, dampReq =
            sdo.requirements.PZDampingRatio("DampingRatio",0.8) creates an
            sdo.requirements.PZDampingRatio object and sets the damping ratio to
            0.8.
Properties
Object Functions
setOvershoot | Set overshoot of sdo.requirements.PZDampingRatio
      object | 
getOvershoot | Get overshoot from sdo.requirements.PZDampingRatio
      object | 
evalRequirement | Evaluate design requirement | 
copy | Copy design requirement | 
get | Get design requirement property values | 
set | Set design requirement property values | 
Examples
Alternatives
Use getbounds to get the bounds specified in a Check
        Pole-Zero Characteristics (Simulink Control Design) block.
Version History
Introduced in R2010b